Skip to main content Skip to search Skip to main navigation
Menu

Capillary columns GC SolGel-1ms™

Description
100% Dimethyl Polysiloxane in a SolGel matrix. Suitable Replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.

  • Less bleed

  • Non-polar

  • Highly inert

  • Same selectivity as BP1

Properties
Film thickness: 0.25 µm
Int. Ø: 0.25 mm
Length: 60 m
Manufacturer Article Number: 054793
Max. temperature programme: 360 °C
Polarity: Nonpolar
Temperature max isotherm: 340 °C
Skip product gallery

Similar products

OPTIMA® 1 high performance capillary columns for GC
100% dimethylpolysiloxanenonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.Similar phases: Permabond® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101.For columns with 0.25 to 0.32mm ID and films
From CHF 782.10*

OPTIMA® 5 capillary columns for GC
5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
From CHF 436.80*

Capillary columns HT8 / Fast PCB
8 % Phenyl Polycarborane-siloxane. Ultra high temperature columns for polychlorinated biphenyl compounds (PCB), nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides and herbicides.
From CHF 721.00*

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.
From CHF 650.00*

Capillary columns BPX-Volatiles
Cyanopropyl Polysilphenylene. Polar phase. For environmental analyses, volatile organic substances, alcohol analyses and for the EPA method 624, USP G43 methods, 502.2, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-VRX, HP-624, OPTIMA 624, ELITE-624, 007-624, RTXVOLATILES, SPB-624, TRV1, CPSIL 13 CB, VOCOL, VB-624, CP-624.
From CHF 1,130.00*

Optima® WAX capillary columns for GC
polyethylene glycol 20000 daltonsUSP G16polar phaserecommended for solvent analysis and alcoholssuitable for aqueous solutionssimilar phases: Premabond® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-WaxMax. temperature for isothermal operation 240°C, max. temperature for short isotherms in a temperature programme: 250°C,for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 782.10*

Capillary, phenyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.
From CHF 193.00*

Capillary, methyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.
From CHF 83.50*

Optima® 5 Amine GC capillary columns for amine separation
especially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.
From CHF 898.60*

Optima® FFAP capillary columns for GC
polyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*