Skip to main content Skip to search Skip to main navigation
Menu

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm

Description
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.

Octyl phases, 10.5 % C, particle size 5 µm.

Properties
Carbon content: 10.5 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 3.0 mm
Length: 125 mm
Manufacturer Article Number: 760701.30
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L7
Volume column: 0.87 ml
pH stability: 1 ... 9
Skip product gallery

Accessories

Guard columns for EC Columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.
Price on request
Skip product gallery

Similar products

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

HPLC Detector lamps
From CHF 635.00*

Preparative HPLC columns Nucleosil®100-5 C18
Grain size 5 µm, pore dia. 100 Å. Octadecyl phase, endcapped, 15 % C.
From CHF 399.10*

EC analytical columns NUCLEODUR® C18 Pyramid, 5 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 5 µm, 14 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C18 Pyramid, 3 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 3 µm, 14 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Pyramid, 1.8 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 1.8 µm, 14 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Isis, 5 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 5 µm, 20 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® Sphinx RP, 3 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 3 µm, 15 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® Sphinx RP, 1.8 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 1.8 µm, 15 % C
From CHF 750.90*

VarioPrep preparative columns NUCLEODUR® C18 Pyramid
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 5 µm, 14 % C
Price on request