Skip to main content Skip to search Skip to main navigation
Menu

Photometer photoLab® and photoFlex®, stored test protocols

Description
A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® Spektral
B: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® Spektral
C: Stored in photoFlex® and photoFlex® Turb®

Reagent-free tests:
Cu - copper plating bath, 690nm, 820nm - copper plating bath - B
CrO3 - chromium plating bath - chromium plating bath - B
Ni - nickel plating bath - nickel plating bath - B
HZ - Hazen colour - Hazen colour - B
IFZ - iodine number, 340nm, 455nm - iodine number - B
m-1 (DFZ) - colouring - FB445 - B, C
m-1 (DFZ) - colouring - FB525 - A, C
m-1 (DFZ) - colouring - FB620 - B, C
FAU - turbidity 620 - T620 - B
E - extinction - extinction - A, B, C
SAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm)

Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®.

Hazardous Substance Data
GHS
Signal word
Gefahr
H-Satz
H290, H314
P-Satz
P280, P301+P330+P331, P305+P351+P338, P309+P310
UNNR
3316
SDS
Link
Properties
Description: Phosphate, PO4-P
For: B, C
GHS: GHS05
Manufacturer Article Number: 252045
No. of determinations: 100
Type: 00798
Unit: 1.0 - 100.0 mg/l
Skip product gallery

Other customers also bought

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Serie and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Serie and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for pHotoFlex®.
Price on request

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Series and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Series and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for photoFlex®.All stored test sets for the photoLab® and photoFlex® photometers can be found in our online shop.Ordering information for all the articles described above and for other articles can be found online.
From CHF 38.30*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.Optics: High-quality Interference FiltersWavelength accuracy: ±1 nm.Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.Automatic switch-off.LCD Display (backlit on keypress).Internal ring memory for 16 data sets.Dimensions (L x W x H): 155 x 75 x 35 mm.Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.Optional: IRiM - infrared interface module for data transfer to computer or printer.*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.**24mm diam. glass cell***10mm diam. multi cell-2
From CHF 508.00*

Tube tests NANOCOLOR® Zinc
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 138.70*

Spectrophotometer NANOCOLOR® Advance
The spectrophotometer NANOCOLOR® Advance, with Reference Detector Technology (RDT), provides precise and reliable measurement and can be used in the entire spectrum of water and wastewater analysis. It can also be used mobile due to its rechargeable battery. With an additional 860 nm LED, the device determines the nephelometric turbidity during each measurement of a tube test and warns of incorrect results.Backlit colored 5" display with touch screenFully automatic cuvette recognition via the integrated 2D barcode scannerEvaluation of NANOCOLOR® tube tests (16 und 24 mm), standard tests (10, 20, 40, 50 mm) and VISOCOLOR® Powder PillowsOver 200 pre-programmed tests and special methods, 99 fully programmable methods, absorbance, transmission, factor, kinetics, 2-point calibration, scan, nephelometric turbidity measurement 1-1000 NTUScope of supply: Spectrophotometer NANOCOLOR® Advance, manual (quick start guide), protective covering, power supply unit with country specific adapters, USB stick, calibration cuvette, certificate, cleaning clothSpecificationsOptical system:Single beam photometer with grating monochromatorWavelength range:340 ... 800 nmWavelength accuracy:± 2 nmWavelength reproducibility:± 0.1 nmSpectral bandwidth: 4 nmPhotometric range:± 3.0 A in the range 340 ... 800 nmScattered light: 0.5 %Light source:Halogen lampData memory:1000 measured values / spectraInterfaces:2 x USB (Host), 1 x USB (Function)Dimensions (W x D x H): 280 x 325 x 130 mmWeigth: 3.8 kgPower supply:110 ... 240 V, 12 V 3A DCProtection class:IP67
From CHF 6,537.40*