Skip to main content Skip to search Skip to main navigation
Menu

Photometers MD 100

Description
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.
  • Optics: High-quality Interference Filters

  • Wavelength accuracy: ±1 nm.

  • Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.

  • Automatic switch-off.

  • LCD Display (backlit on keypress).

  • Internal ring memory for 16 data sets.

  • Dimensions (L x W x H): 155 x 75 x 35 mm.

Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.
Optional: IRiM - infrared interface module for data transfer to computer or printer.
*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.
**24mm diam. glass cell
***10mm diam. multi cell-2

Hazardous Substance Data
SDS
Link
Properties
Description: 2 in 1 Chlorine /pH tablet reagents
Manufacturer Article Number: 278020
Measuring range: 0.01 - 6.0mg/l* / 6.5 - 8.4pH
Skip product gallery

Other customers also bought

Tintometer GmbH

Tintometer GmbH
Photometers MD 100 Boiler Water/Cooling Water
Photometer instruments, specially designed for cooling and boiler water analysis. Thanks to the handy format and the user-friendly indicator chemistry, most of the important parameters can be determined on site. The photometers are supplied pre-calibrated with test methods, simply add the appropriate Lovibond® reagent sets (tablets, powder packs and liquids).Scroll MemoryAutomatic Switch-OffReal-Time-Clock and DateCalibration ModeBacklit DisplayStorage FunctionOne Time Zero (OTZ)Waterproof (IP 68)Scope of supply: instrument in a sturdy plastic case, batteries, 3 glass vials, standard accessories, instruction manual.Please order reagents separately! Please pay attention that some reagents could be used for Boiler Water or Cooling Water only.OpticsLEDs, interference filters (IF) and photo sensor in transparent sample chamberWavelength Accuracy± 1 nmPhotometric Accuracy Photometric Resolution3% FS (T = 20°C - 25°C) 0,01 APower Supply4 micro batteries (AAA), capacity approx. 17 hours or 5000 testsAuto-Offautomatic switch-offDisplaybacklit LCD (on keypress)Storageinternal ring memory for 16 data setsInterfacesinfrared interface for test data transferAdditional Featurereal time clock and dateCalibrationfactory calibration and user calibration. Reset to factory calibration possibleDimensions155 x 75 x 35 mm (L x W x H)Weightbasic unit approx. 260 gEnvironmental conditionstemperature: 5 - 40 °C, rel. humidity: 30 -90% (non condensing)
From CHF 762.00*
Skip product gallery

Accessories

Tintometer GmbH

Tintometer GmbH
Reference standard kits Chloride for photometers MD series
The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly.For instruments with tablet/liquid reagent.
From CHF 89.60*

Tintometer GmbH

Tintometer GmbH
Reference standard kit pH for photometers MD series
The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly.For instruments with tablet reagent.
From CHF 79.30*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Photometers MD 200
Benchtop devices suitable for mobile use. For precise water control through high-precision optics and high-quality interference filters with long-term stable LEDs as light sources.Automatic shutdownReal time clock and dateAdjustment function displayIlluminated LCD-displayFurther photometer versions available on request.SpecificationsMeasurement cycle:approx. 3 seconds (method dependent)Optics:Temperature compensated LED and photosensor intensifier in a waterproof sample chamberKeyboard:4-key polycarbonate film, splashproofDimensions (W x D x H):110 x 190 x 55 mmWeight:455 gPower supply:4 x AAIP code:IP 68pH:6.5 - 8.4
Price on request

Photometers MD 110
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessoriesFurther photometers available on request.SpecificationsOptics:Highly precise interference filters, LEDWavelengths:530 / 560 / 610 / 430 / 580 / 660 nmWavelength accuracy:±1 nmPhotometric range: pH:0.005 A 6,5 - 8,4Data memory:16 measurementsDimensions (W x D x H):75 x 155 x 35 mmWeight:260 gPower supply:4 x AAA micro batteriesIP code:IP 68
From CHF 1,030.00*

Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Series and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Series and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for photoFlex®.All stored test sets for the photoLab® and photoFlex® photometers can be found in our online shop.Ordering information for all the articles described above and for other articles can be found online.
From CHF 38.30*

Accessories NANOCOLOR®, Membrane Filtration
Turbidity elimination before photometric analysis (without digestion). Sample preparation set: 2 syringes 20 ml, 25 CHROMAFIL® membrane filtersMembrane filters CHROMAFIL® without accessories* with glass fiber pre-filter, retention of coarse particles without clogging.
From CHF 146.50*