Roller Apparatus WHEATON® R2P™ 2.0 | Type: Installation kit for WHEATON® R2P 2.0 Roller with top drive, includes temperature sensors and battery backup

WHEATON® Roller Bottle Culture Apparatuses are used in laboratory, pilot plant and production cell culture installations and also meet the expectations of the vaccine and biologic industry. They have a USB downloadable system event log for precise process documentation. The colour touch screen with icon driven interface enables intuitive operation and is easy to view from a distance. The Belt Break Alarm employs two magnetic sensors to ensure that all main pulleys are rotating on the unit. Optional with temperature monitoring and battery backup system. The Battery Backup automatically and seamlessly switches over to battery power to provide rotation for 8 … 18 hours. The Temperature Monitoring/Alarm Option includes two precision temperature probes for real time temperature monitoring and deviation alarms.
  • Digitally controlled maintenance free motor accurate to 0.01 RPM
  • Capable of remote control and monitoring through SCADA systems
  • Multiple decking and capacity configurations available for process flexibility


Specifications:
Capacity:
5 … 88 Positions
Turning speed:
0.25 … 8.1 rpm
Accuracy:
0.01 rpm
Drive:
Belt Driven
Rotation Direction:
right, left, back and forth
Operating Temperature:
10 … 40°C
Power supply:
100 … 240 VAC, 50/60 Hz, 35W
Type: Installation kit for WHEATON® R2P 2.0 Roller with top drive,includes temperature sensors and battery backup

Accessories

DWK Life Sciences Inc.(Wheaton
Accessories for Roller Apparatus WHEATON®
From CHF 2,476.00*

Similar products

Tip

Roller Mixers LLG-uniROLLER 6 easy and pro
Analog or digital tube rollers with 6 rolls for the efficient mixing of biological samples, viscous substances and liquid-solid suspensions. Used in a variety of applications, such as the prevention of blood coagulation, immune precipitation.Max. speed 70 rpmFor gentle rolling of samplesEasy to cleanMax. vessel size 1 litre bottleLLG-uniROLLER 6 easy:Analog controlEasy to useLLG-uniROLLER 6 pro:LCD displayContinuous or timer operationSpecificationsLLG-uniROLLER 6 easy // LLG-uniROLLER 6 proType of movement:rocking and rollingAmplitude:24 mmSpeed:0 ... 70 rpm // 10 ... 70 rpm, adjustable in 1 rpm incrementsTimer:- // 1 ... 1199 minLoad max.:4 kgAmbient temperature:5 ... 40 °CMax. humidity:80 % r. H.Dimensions (W x D x H):260 x 450 x 120 mmWeight:4.5 kg // 5.1 kgPower consumption:25 W // 30 WPower supply:100 ... 240 V, 50/60 HzIP code:IP 21
From CHF 525.30*

Tube roller Roller 6 basic / 6 digital / 10 basic / 10 digital
Roller shaker with 6 or 10 rolls, with smooth rocking and rolling action and a fixed speed. Particularly for mixing blood samples, solid and liquid suspensions and viscous samples. The unit can be used for all conventional tubes and cylindrical bottles. The easy removable rolls allow simple and quick cleaning of the unit from spilled samples.Usable from 4 to 50°C in incubatorsSuitable for continuous operationRemovable rolls make it suitable for larger tubesEasy operation by foil keypadEasy removable rollsRoller 6 digital / 10 digital only:Timer: Countdown, adjustable from 1s to 99h 59minCounter: Display of shaking timeError code displaySpecificationsRoller 6 /10 basic // Roller 6 /10 digitalType of movement:rocking and rollingAmplitude:24.5 (height)Speed: Number of rollers:30 rpm// 5 ... 80 rpm 6 // 10Load max.:2 kgTimer:- // 1 s ... 99 h 59 minAmbient temperature:+4°C to +50°CMax. humidity:80%Dimensions (W x D x H): Roller size (l x Ø):240 x 545 x 115 mm // 380 x 545 x 115 mm 310 x 32 mmWeight:4 kg // 6 kgPower supply:100-240V, 50/60HzIP code:IP 21
From CHF 1,884.00*

Roller mixers RS-TR 5 / 10
These tube roller mixers provide gentle and effective mixing by simultaneous rocking and rolling action. The adjustment and control of speed and time can be done easily via the LCD-Display, with the fully digital version or with a knob in the analog version.Additionally a Timer-Function can be activated via the illuminated LCD-Display of the RS-TR 10.SpecificationsRS-TR 5 // RS-TR 10Type of movement:rocking and rollingAmplitude:17 mmSpeed: Number of rollers:5 ... 70 min-1// 10 ... 70 min-1 6Load max.:4 kgTimer:- // 1 ... 1199 min, continuousAmbient temperature:+4 to +40 °CMax. humidity:80 %Dimensions (W x D x H): Roller size (l x Ø):260 x 490 x 110 mm 280 x 30 mmGewicht:4.5 kg // 5.5 kgPower supply:100 - 240 V, 50/60 HzIP code:IP 21
From CHF 630.00*

DWK Life Sciences Inc.(Wheaton
Accessories for Roller Apparatus WHEATON®
From CHF 2,476.00*

Roller bottles WHEATON®, borosilicate glass, with screw cap
For adherent laboratory cell culture. Meets the requirements of USP Type I and ASTM E-438 Type I, Class A. Autoclavable.
From CHF 574.00*

Roller Apparatus WHEATON® R2P™ 2.0
WHEATON® Roller Bottle Culture Apparatuses are used in laboratory, pilot plant and production cell culture installations and also meet the expectations of the vaccine and biologic industry. They have a USB downloadable system event log for precise process documentation. The colour touch screen with icon driven interface enables intuitive operation and is easy to view from a distance. The Belt Break Alarm employs two magnetic sensors to ensure that all main pulleys are rotating on the unit. Optional with temperature monitoring and battery backup system. The Battery Backup automatically and seamlessly switches over to battery power to provide rotation for 8 … 18 hours. The Temperature Monitoring/Alarm Option includes two precision temperature probes for real time temperature monitoring and deviation alarms.Digitally controlled maintenance free motor accurate to 0.01 RPMCapable of remote control and monitoring through SCADA systemsMultiple decking and capacity configurations available for process flexibilitySpecifications:Capacity:5 … 88 PositionsTurning speed:0.25 … 8.1 rpmAccuracy:0.01 rpmDrive:Belt DrivenRotation Direction:right, left, back and forthOperating Temperature:10 … 40°CPower supply:100 … 240 VAC, 50/60 Hz, 35W
From CHF 1,760.00*

Roller Apparatus WHEATON® Standard
WHEATON® Roller Bottle Culture Apparatuses are used in laboratory, pilot plant and production cell culture installations and also meet the expectations of the vaccine and biologic industry. Optional with Belt Break Alarm and battery backup system. The Belt Break Alarm employs two magnetic sensors to ensure that all main pulleys are rotating on the unit. The unit automatically and seamlessly switches over to battery power to provide rotation for 8 - 18 hours.Smooth ramping digitally controlled rotation accurate to 0.01 rpmBright digital display for easy operationMultiple decking and capacity configurations available for process flexibilitySpecifications:Capacity:5 … 88 PositionsTurning speed:0.25 … 8.1 rpmAccuracy:0.01 rpmDrive:Belt DrivenRotation Direction:right, leftOperating Temperature:10 … 40 °CPower supply:100 … 240 VAC, 50/60 Hz, 35W
From CHF 2,227.00*

Tube roller RM 2
Robust tube roller with gentle tilting and rolling movement. Small space requirement. Suitable for all common tube sizes, bottles and other cylindrical vessels with a diameter of up to 80 mm.Gentle start-up for optimum development of cell cultures.Minimal heat emission, thus no influence on the ambient conditionsCan be used at CO2 concentrations up to 5%.Easy setting of speed and time via LED displayDrip tray and plastic rollers can be removed for easy cleaningOverhead attachment available as accessoryScope of delivery: basic unit including 6 removable plastic rollers and drip traySpecificationsType of movement:rocking and rollingAmplitude/angle:15 mm, 3° fixedSpeed:5 ... 80 rpmMax. load:2 kgNumber of rollers:6Timer:0 ... 99 h 59 min / continuousTemperature range: Max. CO2 range:5 ... 45 °C 5 %Max. humidity:85 %, not condensingDimensions (W x D x H): Roller size (l x Ø):244 x 465 x 115 mm 300 x 32 mmWeight:7.3 kgPower supply:100 ... 240 V, 50/60 HzProtection class:IP 21
From CHF 2,330.00*

Tube Roller Mixer RS-200
There are four models available, two analogue models with either 6 or 9 rollers, with a fixed speed of 33 rpm. Or two more advanced digital models with either 6 or 9 rollers, with digitally controlled speed between 5 and 60 rpm and programmable timer.The rollers conveniently detach to accommodate larger vessels. Recommended for mixing blood samples, viscous substances and liquid-solid suspensions where minimum aeration is required. Units can be used in incubators up to 60 °C and humidity up to 80 %, or in cold rooms down to 4 °C.Rocking and rolling action for complete mixing6 or 9 roller design with footprintWith antimicrobial BioCote protectionSpecificationsRS-200(D) // RS-200(D)-LType of movement:rocking and rollingAmplitude:16 mmSpeed: Number of rollers:33 rpm// 5 ... 60 rpm 6 // 9Load max.:3 kgTimer:continuous // 1 s ... 9 h, continuousAmbient temperature:up to 60 °CMax. humidity:up to 80 %Dimensions (W x D x H): Roller size (l x Ø):565 x 240 x 110 mm // 565 x 360 x 110 mm 340 x 30 mmWeight:5.1 kg // 6.9 kgPower supply:230 V, 50/60 HzIP code:IP 20
From CHF 1,487.20*

Overhead attachment RM 2, PVC
For tube rollers RM 2. With 12 holes at 29,5 mm Ø. Other borings available on request.
From CHF 447.88*